Home ANRITSU | RF Microwave Measuring Instruments Microwave CW USB Power Sensor MA24350A
ANRITSU | RF Microwave Measuring Instruments

Microwave CW USB Power Sensor MA24350A

The MA24350A Microwave CW USB Power Sensor provides precise CW average power measurements from 10 MHz to 50 GHz, with a dynamic range of +20 dBm to -70 dBm. It offers fast measurement speeds of >2,100 readings/s continuous and >5,600 readings/s buffered..

  • Detail
  • Special Features
  • Specification

The MA24350A Microwave CW USB Power Sensor is a highly accurate, compact power meter designed for precise CW average power measurements in the frequency range of 10 MHz to 50 GHz. It features a wide power measurement range from +20 dBm to -70 dBm, making it ideal for both high and low power signal applications. The sensor offers high-speed measurements with continuous sampling at >2,100 readings/s and buffered sampling at >5,600 readings/s. This ensures quick, real-time data collection for modern RF and microwave testing environments.

The sensor can withstand high power levels up to +26 dBm CW and +32 dBm for 10 µs without risk of damage. It features NIST traceable calibrations, ensuring accuracy and reliability. The device's silicone protective covering makes it rugged and field-ready, able to perform well in demanding environments. Additionally, the sensor is compatible with Anritsu handheld instruments and is supported by global calibration and service centers for easy maintenance and support.

  • Wide Frequency Range: Measures from 10 MHz to 50 GHz.

  • Wide Power Measurement Range: +20 dBm to -70 dBm.

  • High-Speed Measurements: >2,100 readings/s continuous, >5,600 readings/s buffered.

  • No Zeroing Required: Operates with no zeroing needed for signals > -45 dBm.

  • High Power Tolerance: Accepts up to +26 dBm CW and +32 dBm for 10 µs without damage.

  • NIST Traceable Calibration: Ensures accurate, reliable measurements.

  • Anritsu Handheld Instrument Compatibility: Works with various Anritsu handheld instruments.

  • Durable Design: Silicone protective covering for enhanced durability in the field.

  • Global Calibration and Service Centers: Available worldwide for calibration and support.

  • Frequency Range: 10 MHz to 50 GHz

  • Power Measurement Range: +20 dBm to -70 dBm

  • Measurement Speed:

    • >2,100 readings/s continuous

    • >5,600 readings/s buffered

  • Maximum Power Tolerance:

    • +26 dBm CW

    • +32 dBm for 10 µs

  • Zeroing: No zero required for signals > -45 dBm

  • Calibration: NIST traceable

  • Compatibility: Anritsu handheld instruments

  • Durability: Silicone protective covering

  • Temperature Range: -10°C to +60°C

  • Weight: Approx. 300g